Table 2 A comparison of theory with experiment for the particle range enhancement due to sonication

From: Theory for acoustic streaming in soft porous matter and its applications to ultrasound-enhanced convective delivery

Experiment Distance enhanced − mm (meas) Experimental sonication time (min) Theoretical sonication time (min)
[33] 1 2 2.5
[34] 3 4.5 0.5
[35] 0.14 30 35
[36] 0.35 30 28
[37] 1.37 140 24 days?? see text
Cornell-Weill(2017)* 1.3 2 6
Therataxis (2017)* 2.5 105 800