Fig. 3 | Journal of Therapeutic Ultrasound

Fig. 3

From: High-intensity focused ultrasound ablation enhancement in vivo via phase-shift nanodroplets compared to microbubbles

Fig. 3

Maximum temperatures measured at the focal target and at the skin. a The temperature map during a control sonication was overlaid on the corresponding MR image of the rat including the liver. Two regions of interest were defined for quantitative regional analysis: b the target (focus of the HIFU beam), and c the surface of the animal. The gray solid line indicates the mean temperature change observed when HIFU was applied without an injection of perfluorocarbon agents (sham control experiments), and the dotted lines indicate one standard deviation. The asterisk indicates significance (p < 0.05) compared to the sham control results. The dagger indicates significance (p < 0.05) between microbubbles and nanodroplets. The data is displayed as mean ± S.D., where n = 3 to 5 (see Table 1)