Skip to main content

Table 2 Spatial accuracy characterization with the rat model

From: Trans-cranial opening of the blood-brain barrier in targeted regions using astereotaxic brain atlas and focused ultrasound energy

  Atlas spacing (mm) Measured spacing (mm) Percentage error
Rat A Rat B Rat C Rat D Rat E
Medial/lateral 3.32 3.5 3.1 3.0 3.1 3.1 ±6.02
4.03 4.2 4.4 4.0 4.1 3.9 ±4.96
Superior/inferior 5.55 5.1 5.4 5.7 5.7 5.7 ±3.78
4.37 4 4.5 4.1 4.5 4.3 ±4.44
Anterior/posterior 3 3.2 3.1 2.9 2.9 3.2 ±4.67
6 6.1 5.9 5.8 5.8 6.1 ±2.33